High Productivity Clinical Chemistry Analyzer |
|
![]() |
|
α-CHEM is an innovative direct reading clinical chemistry analyzer. The 3-plate coaxial structure and an efficient multitasking system allows for high performance and flexibility within a compact instrument. A reduced reagent consumption combined with an advanced cuvette washing station assures low running costs. This high productivity chemistry analyzer is ideal for medium sized laboratories or as an essential back-up in a large institution . |
|
Key features and benefits: 300 tests/hour (420 tests with ISE) No consumables and low reagent volume: low cost per test; Limited water consumption and use of normal distilled water: low running costs; Use of various primary sample tubes: flexible integration in sample handling process; Patient identification; Pre-dilution and automatic rerun; Reagent barcode scanning; Primary tubes; Level sensing. |
![]() Simple and intuitive software under Windows ® |
The 3-plate coaxial structure. |
|
| TECHNICAL
CHARACTERISTICS
|
|
| OPERATIVE MODE: |
Innovative 3-plate coaxial structure;
Random, Batch, STAT, Profile |
| THROUGHPUT: |
300 tests per hour, up to 420 tests with ISE unit
(optional). |
| SAMPLE PLATE: |
59 test tube positions (5, 7, 10 ml), 59 serum
cups (sample, calibrator, control); internal barcode reading; sample
volume from 3 to 40 |
| REAGENT SYSTEM: |
35 reagent positions (mono or bi-reagent); refrigerated
reagent plate compartment (Peltier elements), preheated reagent needle
with integrated level sensor, internal barcode reading, reagent consumption
from 350 µl per test. |
| SAMPLE PRE-DILUTION: |
Pre-programmable dilution ratio, post-dilution
ratio for pathological samples. |
| CUVETTE SYSTEM: |
60 position reaction plate, semi-disposable cuvettes,
optical path 7 mm, measuring temperature 37°C, hydraulic heating
system contolled by Peltier elements, minimum test volume 300 µl. |
| WASHING STATION: |
9 needle cuvette washers, 1 piston pump cuvette
drier, water consumption 800 ml/hour, automatic cuvette check before
re-use. |
| WAVELENGTH RANGE: |
8 position filter wheel, automatic filter selection
(340,405,492,505,546,578,630,700), other wavelength available on request |
| PHOTOMETRIC RANGE: |
Linearity from 0 to 2.5 O.D., photometric sensibility
0.001 A. |
| ANALYTICAL MODES: |
Kinetics, end point (bichromatism option), fixed
time, differential, multistandard, graphical plot for all measurements,
calculated mode. |
| QUALITY CONTROL: |
Different controls can be defined for each test,
Levey-Jennings graph, Westgards rules. |
| BAR CODE READER: |
Code 128, codebar. |
ISE UNIT: |
Na, K and CL measurements. |
SYSTEM INTERFACE: |
RS 232 serial interface bi-directional for remote
access, usb, ethernet ports. |
LANGUAGES: |
Multilanguage capability. |
PRINTER: |
Any standard PC printer can be connected. |
ENVIRONMENT: |
Working temperature from 18 to 35°C, relative
humidity from 10 to 90%. |
POWER SUPPLY: |
110/220 V, 1Kw max. |
DIMENSIONS: |
(W) 110 x (D) 107 x (H) 71 cm ; WEIGHT: 65 Kg.
FLOORSTANDING |
|
All illustrations and
specifications contained in this folder are based on the latest information
available at the time of printing. IMMUCHEM reserves the right to make changes to materials, equipment and models, and to discontinue models at any time without notice |